Customization: | Available |
---|---|
After-sales Service: | Remote Support |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
IWILDT-AI48002800H large container security inspection system machine is specially designed for security inspection of container loaded goods at customs, ports and border ports. It reduces the labor-intensive and time-consuming safety inspection of trucks, containers and vehicles, generates images of the material, volume and quantity of the goods filled in the container through X-ray fluoroscopy scanning, and checks whether there are threats such as explosives, drugs, weapons of mass destruction (WMDs) and contraband.
IWILDT-AI48002800H large container security inspection system machine uses adjustable electron accelerator from 4 MeV to 7.5 MeV, with penetrating force of 330 mm steel plate. In the pass scanning mode, up to 100 vehicle containers per hour are scanned for security inspection.
IWILDT-AI48002800H large container security inspection system machine X-ray Array Image Detection and Imaging System has a high-speed image data acquisition circuit up to 0.8Om/s. After image processing by computer software, the different densities and shapes of cargo loaded in the container are displayed in pseudo-color gray level. Operators can quickly and reliably examine and analyze images through high resolution LCD monitors.
IWILDT-AI48002800H large container security inspection system machine can customize the detection frame width and height to meet the special requirements of users.
IWILDT-AI48002800H large container security inspection system machine is easy to operate and occupies a small area with low requirements for external infrastructure, which can meet the most stringent international safety inspection standards.
The selected equipment has automatic radioactivity detection (ARDmu), which can simultaneously perform X-ray examination and analysis to detect the presence of radioactive gamma and/or neutron materials.
Product parameters
Electron induction accelerator
Ray energy: 4 ~ 6mev;
Irradiation direction: side illumination type;
Working mode: high energy and low energy alternate beam output
Operating frequency: 400Hz
Penetrating steel plate: maximum 330mm thick steel plate;
Heat dissipation mode: air conditioning ventilation duct type and oil immersed type;
Radiation protection: 200mm thick lead tank;
Scattering angle: 80 degrees;
Control mode: RJ45 network port communication code control;
Collimator: Electric "shutter" device, ultra narrow slit beam output;
Detection system
Detector: SIPM photon counting detection system
Counting range: 0 ~ 60000 photons
Structural design: modular, removable, secondary handling;
Color coating: Mirror blue gray or fan color;
Appearance dimension: 8.60m (L) x 3.3m (W) x 6.8m (H);
Channel size: 2.8m (W) x 4.8m (H);
Equipment weight: 2T;
Detection crystal: CdWO4;
Photoelectric conversion: CMOS;
Data width: 10 bits;
Number of pixels: 1920;
Pixel arrangement: L-shaped line array;
Cascade mode: jr45 communication mode;
Image processing
Image workstation: I7/8G/4TB hard disk/24 inch 20000:1/LCD;
Software functions: edge enhancement sharpening, image inversion, histogram equalization, storage image review, color/black and white, local increase, excessive increase, organic matter removal/inorganic matter removal, brightening/darkening, enlargement/reduction, real-time video;
Picture format: JPG, image name according to scanning time;
License Plate Recognition: License Plate Recognition and Image Classification and Archiving;
Data storage: 500000 images as standard;
Data archiving: DVD recorder (standard);
Printer: color laser printer;
Equipment performance
Vehicles tested: less than 18m (long) X 2.5m (wide) X 4.6m (high);
Scanning mode: Head avoidance, departure-free detection scanning mode for passengers;
Pass rate: 60 cars per hour;
The absorbed dose was less than 1 uSv/time.
Scanning speed: 5 km/h; 10 Km/h in fast detection mode;
Penetration force: After penetrating 320mm steel plate, the outline of 200X200X100mm lead field can be seen.
Spatial wire resolution: steel wire with diameter less than 1.5mm;
Wire penetration resolution: steel wire less than 3 mm can be seen after 100 mm steel plate;
Contrast sensitivity: 100 mm steel plate can be seen less than 1 mm steel sheet;
Workplace: 50m (long) X 20m (wide);
Working temperature: - 20 degree C to + 43 degree C (- 25 degree C to 50 degree C in option);
Storage temperature: - 30 C to + 55 C;
Relative humidity: 0 to 95%;
Waterproof grade: IP45;
Power consumption: average 24 kW;
Monitoring: Camera (including a PTZ) +radio intercom;
Warning: Tri-color safety lights + sirens;
Standards: Compliance with World Health Organization, ICRP 103-2007, China, EU and US regulations;